Home > Machinery & Industrial Supply > Industrial Machinery > Hicool - Refrigeration Industry

Products Information

Hicool - Refrigeration Industry

Description:

Integrant Mobile Cooling Unit For Internal Installation Integrant Mobile Cooling Unit For Internal Installation Series Cooling Capacity: 3.5 - 15 kw Air Flow: 1200 -5000 m3/h Power Supply: 220V AC or 48V DC Refrigerant: R22/R407C/R410A Outline HICOOL Integrant Mobile Cooling Unit For Internal Installation(HMC) product application is based on our enormous wealth of experience in mobile telcommunications,it is designed and made to provide environmental close control tolerances within conditioned space,such as Mobile phone stations, the base stations of mobile phone networks cool around the clock 365days a year. Hicool HMC products are renowned for their quality and reliability with their prouded track records,the unit is fully controlled by our advanced microprocessor controller to provide a highly demanding temperature,humidity,air volume and cleanness controlled envirnment . Feature Integrant mobile cooling units 1) High Sensible Heating Capacity Rate Hicool Mobile Cooling units sensitive heating capacity rate is more than 85% ,specially for the design of removing a large number of heat which is outflow by precision electronic equipments.Compared to the comfort air conditioner HICOOL mobile cooling units could save Energy consumption by 30%--40%. 2) High reliable design,safety and reliable operation Considering mobile cooling units environment and the multiformty of work demands, the particular reliable design and technics ensure the unit operating day and night of all-year. 3) Lasting anti-corrosion The cabient of the unit is made of galvanized steel to make sure long life. 4) Unaltered temperature and humidity Automatic Humidifier and electric heater epuipment for optional. 5) Advanced automatic controll,remote monitoring the automatic design appropriated the building feature of Chinese base station has self-diagnostic function . RS 485 stardand communication interface . Unattended at the scene , actualize remote monitoring management. 6) Automatic head pressure control permits operation down to -20 ambient The internal unit configure stardand automatic condensate pressure controll device, Multi-point control ,no effect even the drastic changes in ambient temperature ,operation all day.(stardand units can efficient operate in the lowest temperation -5 C,low temperature units can stably work in the temperature -25 C. 7) Three speed adjust The unit adjust the temperature of supply air automaticly according to the operation condition.High speed supply air provide the most air and cooling capacity,Low speed supply air provide the the largest dehumidifier capacity. 8) Free cooling,saving energy With the free cooling elements can absorb the cold air of outside into room for cooling the interner temperature, saving the energy and extending the life. 9) Auto-restart function when power cut When the power supply is restored after cutted,the host return to normal work automatically. 10) Run/Standby and duty rotations. Integrant mobile cooling unit for internal installation HICOOL HMC product application is based on our enormous wealth of experience in mobile telcommunications,it is designed and made to provide environmental close control tolerances within conditioned space,such as Mobile phone stations, the base stations of mobile phone networks cool around the clock 365days a year. Hicool HMC products are renowned for their quality and reliability with their prouded track records,the unit is fully controlled by our advanced microprocessor controller to provide a highly demanding temperature,humidity,air volume and cleanness controlled envirnment . Feature: a. Cabinet use anodized extruded aluminum frame and the panel is electrostatic painted galvanized sheet steel. b. High performance 48DC fans for optional c. Front or bottom air discharge d. Electrical heater e. Advanced intelligent control technology f. Optional available with non-ozone depleting R407C and R134a refrigerants. g. Adjust the speed of the fan h. The record of all alarm/query(up to 300) i. Compose cetral monitoring and remote monitoring systems (stardand RS485) j. Setting and revision the parameter becomes easy because of the panel keys (Three-tier password) k. All the HMC units have direct free-cooling and dual powersupply,optional for 220VAC and 480VDC. l. Extra-wide input voltage range m. high reliability and flexibility n. Provide a high sensible heating ratio to ensure a proper running of the equipments. o. Automatically starting whenever the electricity is reconnected.when energizing the unit,it will start with a delay from 2 to 6s,selected in a casual way,in order to avoid under any conditions,the simultaneous starting of several units. p. Autochangeover controls for balanced use in twin-unit applications provide q. front maintenance access r. Copeland scroll compressors with built-in electric protection crankcase. s. A unique and flexible economic operation model. All factory pre-piped,wired,and tested,ready for final piping and wiring conncections at the sit.

Contact Information

Company: Huizhou Hicool Climate Equipment Co., Ltd

*Tell your suppliers you found them on tootootrade

You May also Like
All Categories +